Both REST and SOAP services honor this property. If not specified, the default cache size is 200,000. This increases the speed of tile retrieval for cached services. If you do add or change the property, manually restart ArcGIS Server for it to take effect.Īn integer that specifies the number of users whose token information will be cached. It is recommended that you do not enable this property, as it carries a security vulnerability. By default, the property is not listed and its value is false. Starting at 10.7, double quotation marks " are also allowed in URL query strings when this property is set to true. When added and set to true, braces, brackets, or pipe | special characters are allowed in URL query strings unencoded. Beginning at 10.4, only administrators can publish extensions and geoprocessing services by default. If singleClusterMode is set to false and all machines are restarted, the legacy architecture will be used.ĪllowGPAndExtensionPublishingToPublishersĪllows both publishers and administrators to publish geoprocessing services and extensions if set to true. Background Image - choose a background image to be displayed on the P-CCS Web Interface.The AppServer property is relevant only when the singleClusterMode deployment is set to true.User Data - eight "User Data" property fields are provided for user specified data for sorting and filtering.Expose System Errors on BACnet - when set to No (default setting), Paradigm device errors will not report to the connected BACnet system.BACnet UDP Port - the port number used for connection between the Paradigm system and a connected BACnet IP system.The default value of 108 only needs to be changed if there will be device instance number conflict with another device on the BACnet network. BACnet Device Instance - the Paradigm BACnet instance number when viewed by a BACnet client application.Check Conductor for UPS - when enabled, allows a graceful shutdown of the P-CCS and Net3 Conductor on APC UPS's that support this feature.Click inside the property to change the time setting. "Backup Time" - default is "12:00 am".When "Enabled is set, the "Backup Time" property is enabled for selection. Click inside the Disabled property to change the setting to "Enabled". "Daily Backup" - default is "Disabled".Conductor SPCF Backup - includes backup schedule settings of the Server Project Configuration File (.*spcf) to the connected Net3 Conductor.Typically, this product IP address is set to factory default 10.101.50.60. Net3 Conductor Connection 1 - address of the Net3 Conductor Network Services Gateway.Note: All Paradigm products, by default, participate in Net3 logging (mainly for errors). The P-CCS always serves time to its Paradigm Architectural Control Processors (P-ACP) using its own time, provided by the Net3 Conductor Network Services Gateway, or other external service at the specified address. External Timeserver - this is the IP address of the external time server, if any.If this is set to Automatic, and DHCP should provide the Gateway IP and both the primary and secondary P-CCS network interfaces.Options include "Manual" for user applied unused IP address or "Automatic" allowing DHCP assignment if it will be supplied by DHCP service. Shared Gateway IP - displays the current gateway IP for the Central Control Server, primary and secondary network interfaces.Typically the secondary network port on a P-CCS is used for interface to a BACnet system. Options include "Manual" for user applied unused IP address or "Automatic" allowing DHCP assignment. Secondary Network Config - displays the current network IP address selection for the Secondary Network (NIC) interface on the P-CCS.Tip: If "Automatic" is the selected address method, this means that Link Local IP settings are used when no DHCP service is found on that interface.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |